SM 3000 DALTON UPS

8,585 EGP
Out of stock
Reward points: 4293 points
Get a Quote for your company
Call Us
Chat Us With Whatsapp
Payment options
Brand :
DALTON

Model SM10
600VA
SM10
1200VA
SM10
1500VA
SM10
2000VA
SM10
3000VA
Rating Power 600VA/360W 1200VA/720W 1500VA/900W 200VA/1200W 3000VA/1800W
Input Input system Single Phase
Voltage range 176-276VAC (100% load), 120-276VAC (50% load)
Power factor ≥0.99
Frequency 50/60Hz
Output Output system Single Phase
Rated voltage 208*/220/230VAC
Power factor 0.6
Voltage precision ±2%
Voltage distortion < 1% THDV on linear load
< 5% THDV on non-linear load
Output wave form Simulated Sinewave
Output frequency 50/60Hz (±10%)
Inverter overload
capacity
(Utility power,25©)
100-105%: no alarm
105-125% : load transfers to Bypass mode after 10 minutes
125-150% : load transfers to Bypass mode after 30s
Transfer time 0ms
Crest factor 3:1
DISPLAY/ INTERFACE LCD Display LCD Display indicates frequency, voltage, load, battery voltage, etc. LED indicates running status
LED Status Indicator Utility power; Battery discharge; Inverter On
External Communication USB/RS485 and (RS232 and SNMP adapter are optional)
PARALLEL No
Communication
software
Windows XP/ 2003 and later version; Linux; Unix
Optional EX SNMP / dry contact relays / Modbus
Battery Batteries voltage 12VDC 24VDC 24VDC 48VDC
Battery Type Sealed maintenance-free lead –acid battery
Backup Time
(25℃)
Full load ≥ 5min (Standard)
Battery quantity 1 2 2 4
General Temperature 0 ~ 40℃
Humidity <95% (non-condensing)
Altitude <1000m
Efficiency >90% (Line mode), >92% (Battery mode), >96% (Eco mode)
FUNCTIONS Expandable Battery Modules, LCD
Noise (dB) <35dB
Protection Low battery, overload, over temperature, short circuit, output over voltage, output low voltage
L*W*H (mm) 290 x 100 x 140 345 x 140 x 170 380 x 125 x 225 400 x 170 x 250
Weight (kg) 5 9 10 14 20

SM 600 (Dalton_SM10.pdf, 708 Kb) [Download]

No reviews found